Metrological requirements for hardness testers / hardness meters

Aug 10, 2026 Leave a message

The metrological requirements for hardness testers are primarily aimed at ensuring accurate and stable measurement results that comply with relevant national metrological verification regulations or calibration specifications. Different types of hardness testers must be verified or calibrated according to their specific requirements; for instance, Rockwell hardness testers for metals are subject to JJG 112-2013, Brinell hardness testers to JJG 150-2005, and Vickers hardness testers to JJG 151-2006. These regulations set forth specific criteria regarding equipment structure, test forces, indenters, and indicated values.

 

During actual metrological inspection, the hardness tester's appearance and mechanical structure are examined, and components such as the spindle, specimen stage, and loading mechanism are tested. Furthermore, the test force applied by the instrument must remain stable and stay within specified permissible error limits. Taking the Brinell hardness tester as an example, regulations specify requirements for spindle perpendicularity, coaxiality, test force, and the indentation measurement device, with the test force error strictly controlled within the prescribed range.

 

The indenter and measurement system are also critical aspects of metrological inspection. Since the indenter's shape, dimensions, and surface condition directly influence test results, they must be regularly checked for wear or damage. For Brinell hardness testers, the resolution and measurement error of the indentation measurement device must be verified; for Vickers hardness testers, it is essential to ensure that the diamond indenter and the indentation diagonal measurement system meet the relevant standards.

 

The instrument's indication error and repeatability should also be checked using standard hardness blocks. Newly purchased or repaired equipment generally requires an initial verification or calibration, while instruments in regular use must undergo periodic subsequent verification or in-service checks. Metrological inspections should be conducted promptly if significant deviations in test results or degraded repeatability are observed, or if the instrument has been subjected to impact or returned to service after repairs. These measures ensure the reliability of hardness test data, providing a valid basis for material inspection and product quality control.

Send Inquiry

Send Inquiry